CANBus CH Calibration-single function r2, Instrukcje obsługi - Manuals, Yanmar, BY2, Unlimited System

[ Pobierz całość w formacie PDF ]
CANBus Single Function Control Head Calibration (with software > v1.09)

This calibration procedure is for Single Function controls. This type of control has shift for one engine on a lever and throttle for one engine on a different lever. The CH4400 and CH5600 are typical for this type of control.

 

SINGLE Engine CONTROL HEADSingle Function - Single Engine Controls

-       With the system OFF (no power on the CANBus) press and hold the N (NEUTRAL) button on the CP1100 control panel and turn the power ON. The Neutral lamp will blink.

-       Move the THROTTLE lever to the FULL THROTTLE (WOT) position. The Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the THROTTLE lever to the IDLE position. The Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the SHIFT lever to the FORWARD position. The Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the SHIFT lever to the NEUTRAL position. The Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the SHIFT lever to the REVERSE position. The Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on. The Select and Neutral lamps will both blink indicating the process is complete. Turn the power OFF to exit the calibration process.

 

 

DUAL or TRIPLE Engine CONTROL HEADPORT Engine

-       With the system OFF (no power on the CAN Bus) press and hold the PORT N (NEUTRAL) button on the CP1200 control panel and turn the power ON. The Port Neutral lamp will blink.

-       Move the PORT THROTTLE lever to the FULL THROTTLE (WOT) position. The Port Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the PORT THROTTLE lever to the IDLE position. The Port Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the PORT SHIFT lever to the FORWARD position. The Port Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the PORT SHIFT lever to the NEUTRAL position. The Port Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on.

-       Move the PORT SHIFT lever to the REVERSE position. The Port Neutral lamp will blink. Press the SELECT button. The Select lamp will turn on. The SELECT and Port Neutral lamps will both blink indicating the process is complete. Turn the power OFF to exit the PORT calibration process.

 

STARBOARD (STB) Engine

-       With the system OFF (no power on the CAN Bus) press and hold the STB N (NEUTRAL) button on the CP1200 control panel and turn the power ON. The STB Neutral lamp will blink.

-       Move the STB THROTTLE lever to the FULL THROTTLE (WOT) position. The STB Neutral lamp will blink. Press the SYNC button. The SYNC lamp will turn on.

-       Move the STB THROTTLE lever to the IDLE position. The STB Neutral lamp will blink. Press the SYNC button. The SYNC lamp will turn on.

-       Move the STB SHIFT lever to the FORWARD position. The STB Neutral lamp will blink. Press the SYNC button. The SYNC lamp will turn on.

-       Move the STB SHIFT lever to the NEUTRAL position. The STB Neutral lamp will blink. Press the SYNC button. The SYNC lamp will turn on.

-       Move the STB SHIFT lever to the REVERSE position. The STB Neutral lamp will blink. Press the SYNC button. The SYNC lamp will turn on. The SYNC and STB Neutral lamps will both blink indicating the process is complete. Turn the power OFF to exit the STB calibration process.

 

  [ Pobierz całość w formacie PDF ]
  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • agul-net.keep.pl